| AC Inputs | Nominal: 120V/200V, -240VAC. 60/50Hz. Operating: 90V-132VAC or 180-264VAC, 47-63Hz. |
| Fault Reset Time | A latched fault shut-down requires an interruption of the AC input for one second to reset or cycling of R.O.F. |
| Efficiency | The efficiency is greater than 75% at full load (typically 78%). |
| Fusing | The AC supply shall be fused externally with a 7A or 10A, 250V CSA/UL. |
| Inrush Current | Inrush current will be less than 30 A, averaged over first half cycle from a cold start on AC, or 8A on DC. |
| Shut-down Input | An optional input is available to force latched shut-down for remote over temperature or fan failure
detection applications (100 PTC, normally closed contact or open collector gate required).
The AC input (or optional ROF) must be recycled to reset. |
| Output Protection | All outputs are fully protected. The DC input or R.O.F. must be recycled to reset fault shut-down. |
| Remote ON-OFF | Logic level remote power ON-OFF capability is available. The input is TTL compatible, or it may be connected to a switch or open collector gate without pull-up. Standard level is ON low. |
| Dynamic Load: | A 7 Amp step (or 70% of the full load current, whichever is less) on the +12V rail or +24V rail results in
an output voltage transient of less than 3%. |
| Start Up | Turn on delay at nominal input is about 0.8 seconds. Output rise time is under 50 mS. at low line the delay
is somewhat longer due to safety circuit. |
| Hold-Up | Hold up time is 15mS at 90V (180V) input, and increases with higher applied voltage. Longer times are optional. |
| Temperature | Operating: 5oC to 50oC with minimum 30 CFM airflow lengthwise. Non-Operating: -5oC to 75oC. |
| Remote Sense | Compensates up to 0.25V total on the +5V channel. |
| Power Fail Warning | Active low, approximately 5mS warning. |
| MTBF | The power supply has an DMTBF greater than 1,000,000 hours at 30oC. |
| AC Connector | Molex 5219 series (15-31-1036). |
| Output Connectors | Two 10-32 studs for output1; Molex Mini-Fit, Jr series (39-28-1103) for balance on most versions |
| Certifications | UL1950 Recognized; CSA C22.2 No.950 & CSA C22.2 No.234 certified; licensed by TUV to EN 60950 & DIN VDE 0805. Meets: VDE 0871, FCC Rules Part 15 Subpart I, Class A. |